Power Quality Management Software
Continuously monitors voltage sags, harmonics, flicker and unbalance; automatically audits against EN 50160 and regulatory power quality criteria, and produces audit-ready reports.
GeoEner PQM is power quality management software that measures, monitors and proves the technical quality of the electricity grid. It collects vendor-independent data from field power quality analyzers via Modbus, OPC UA and REST, and standardizes all measurements in a single time-series archive with 10-year retention. It captures voltage sags, swells, interruptions and transients at millisecond resolution with instant alarms, and automatically audits voltage magnitude, unbalance, harmonics and flicker using EN 50160 and IEC 61000-4-30 methodology. Regulatory power quality reports (standard tables, weekly voltage sag table, raw data export) are produced in one click; measurement points are scored against regulatory limits, pinpointing weak spots per feeder and transformer. Root cause analysis helps distinguish whether a disturbance originates upstream (grid) or downstream (consumer). Reports are available as PDF, Excel, CSV and HTML, can be pushed to SAP-side services via EDVARS integration, and delivered by scheduled e-mail. Built for distribution companies, industrial facilities, organized industrial zones and large consumers; supports LDAP/SSO and role-based authorization.
Continuously monitors voltage sags, harmonics, flicker and unbalance; automatically audits against EN 50160 and regulatory power quality criteria, and produces audit-ready reports.
Module by module.
Captures voltage sags, swells, interruptions and transients at millisecond level and raises instant alarms.
Automatically audits voltage magnitude, unbalance, harmonics and flicker using the standard measurement window.
Standard tables 1/2/3/5, the weekly voltage sag table and raw data exports — produced audit-ready.
Scores measurement points against regulatory limits and pinpoints weak spots per feeder and transformer.
Helps determine whether a disturbance originates on the grid side or the consumer side.
Standardizes power quality recorders of any brand and model in a single database.
Tracks individual harmonics, total distortion and negative sequence, with optional IEEE 519 voltage/current auditing.
KPIs, event trends, the weak-spot list and a live map bring the state of the grid onto a single screen.
Ready-made regulatory templates stay audit-ready at all times, with automatic performance scoring charted over weekly and monthly windows. Prepared reports are pushed to SAP-side services through EDVARS integration and delivered straight to stakeholders by scheduled e-mail.
Measurements are taken from power quality analyzers over Modbus, OPC UA and REST, independent of brand and model.
All measurements are standardized in a single database and archived for 10 years with compression and retention policies.
EN 50160, regulatory and IEEE 519 criteria are audited, and a performance score is computed for each measurement point.
Output is produced through dashboards, regulatory reports and EDVARS export; reports reach stakeholders by scheduled e-mail.
Audit technical quality obligations automatically, produce regulatory reports in one click and target weak feeders precisely.
Spot sags and harmonics affecting the production line early, identify their source and reduce losses.
Monitor quality issues on the shared grid and clarify liability boundaries with data.
Yes, GeoEner PQM uses a device-independent adapter architecture to collect data from analyzers of any brand and model over Modbus, OPC UA and REST. All measurements are standardized in a single time-series database, so data from different devices is audited against the same criteria and monitored on the same dashboards.
Reports are pushed to SAP-side services through EDVARS integration and delivered straight to stakeholders by scheduled e-mail. Output is available as PDF, Excel (.xlsx), CSV and HTML. Automatic performance scoring is charted over weekly and monthly windows.
GeoEner PQM's root cause analysis helps determine whether a disturbance originates upstream (grid side) or downstream (consumer side). Measurement points are also scored against regulatory limits, pinpointing weak spots per feeder and transformer. This helps clarify liability boundaries with data, especially on grids shared with industrial zones and large consumers.
Measurements are kept for 10 years in a time-series archive with a compression policy. Access connects to corporate authentication through LDAP/SSO and is governed by role-based authorization.
All products run on the same map, the same authorization model and the same asset records.
Inspection Management
Inspection Management: Drone and AI Grid Inspection
View detailsOutage Management
Outage & EPDK Reporting
View detailsInvestment Management
Optimize your electricity distribution investments
View detailsMaintenance Management
Digitize your asset maintenance processes
View detailsGrid Monitoring
Power System Management
View detailsGIS · Network Topology
Network Inventory, Topology and Feeder Management
View detailsDigital Twin · 3D
3D Grid Twin and Scenario Analysis
View detailsEngineering Analysis
Line Project Engineering Calculations
View detailsBusiness Intelligence
Management Dashboard, Benchmarking and Monitoring
View detailsField Operations
AKIM Field Management Application
View detailsFault Management
Fault Reporting and Response Management
View detailsTrusted By