Plant Work Orders, Failure Records and Service Reports
Work order and failure management for plant assets: preventive, corrective and inspection work orders, assignment to field crews, checklist-driven field execution, operator acceptance, repair work orders from failure records, and one-click service report and acceptance protocol PDFs.
GeoEner EAM Work Orders and Failures follows every job on a plant asset from creation to operator acceptance. A work order is opened as preventive, corrective or inspection with one of four priority levels; it can be created manually, from a need on the maintenance calendar or from a failure record. A second work order can never be opened from the same maintenance need or failure. EAM work orders are kept separate from distribution grid work orders and isolated per tenant.
A work order is assigned to a user, and field crews can list only the work orders assigned to them. When work starts, the system checks that the required HSE permits are approved and valid, that the person doing the work holds a valid certificate for those permits, that every isolation point is verified, and that a valid crane reservation exists if a crane is required. In the field the checklist is filled in: check, measurement, text, photo and signature items; when an item deviates and is configured to do so, a failure record is opened automatically. Work cannot be completed until required items are answered and isolations are restored.
Technically completed work goes to the operator for acceptance; the operator accepts it or sends it back with a reason. Cancellation and rejection require a reason, and every status change is written to history with who, when and which note. The service report and the operator acceptance protocol are downloaded as PDFs from the work order detail; the report compiles work order, SLA, permit, isolation, checklist, material, failure, downtime and status history sections in the language of the request.
Failure records are kept with technical class, severity, reporting source and whether they caused a production stop. When a repair work order is opened from a failure, the failure counts as in repair; once the work order is accepted, it is resolved, and if the work order is cancelled, it goes back to open. A failure causing downtime and a maintenance work order requiring shutdown open and close the downtime record automatically.
Work order and failure management for plant assets: preventive, corrective and inspection work orders, assignment to field crews, checklist-driven field execution, operator acceptance, repair work orders from failure records, and one-click service report and acceptance protocol PDFs.
Module by module.
A work order is opened for a plant asset with type, priority, planned start and checklist template. A work order raised from a maintenance need inherits the plan's permit types, wind limits and crane requirement, and no second work order can be opened from the same source. Decommissioned assets cannot get work orders.
A work order is assigned to the user who carries out the job; field crews can list only the work assigned to them on the work orders screen. The assignee's certificates are checked against the permit types the job requires, both in the list and at start.
Work cannot start unless required HSE permits are approved and valid, the assignee holds a valid certificate, isolation points are verified and, for crane jobs, a valid reservation exists. It cannot be completed until required checklist items are answered and isolations are restored.
Checklist items are answered while work is in progress, and photos and signatures are attached as files. A not-OK or out-of-range answer is marked as a deviation; if configured, a failure record of the defined severity is opened automatically and linked to the item.
Technically completed work goes to the operator for acceptance, who accepts it or sends it back with a reason. A reason is required for rejection and cancellation, and every status change is written to the work order history with user, time and note.
The service report is generated server-side as a templated PDF with work order, SLA, work permit, isolation, checklist, material, failure, downtime and status history sections. The acceptance protocol is available only for technically completed or accepted work orders; texts follow the request language.
A failure is recorded as mechanical, electrical, hydraulic, control system, structural or external; minor, major or critical; reported manually, from inspection or from an alarm. Symptoms, root cause, detection time and closing note are kept, and critical failures are counted separately on the dashboard.
A repair work order is opened from a failure in one step. When it is opened the failure is in repair, and when it is accepted the failure is resolved; if the work order is cancelled, the failure reopens. A failure that causes downtime opens a downtime record from detection until resolution.
The work order is opened with type, priority and checklist; permit and limit data carry over from the source.
The job is assigned to a user with suitable certificates; field crews list their own work.
Work starts once permit, certificate, isolation and crane conditions are met.
Measurements, photos and signatures are entered; deviations open failures and isolations are restored.
The operator accepts the job; the service report and acceptance protocol are downloaded as PDFs.
See field work with checklist evidence and record acceptance or rejection with a reason.
List the work assigned to you, fill in the checklist and attach photos and signatures.
Produce the service report and acceptance protocol from the work order; contracted work runs from the contractor screen.
A work order cannot start if the required HSE work permits are not approved and within their validity window, if the assignee lacks a valid certificate for those permit types, if not every isolation point has been verified, or if a crane job has no currently valid crane reservation. Work orders cannot be opened for decommissioned assets either.
Field crews list the work orders assigned to them and fill in the checklist: check, numeric measurement, text, photo and signature items. An out-of-range measurement or a not-OK answer is flagged as a deviation, and if configured a failure record of the defined severity is opened automatically. Work cannot be completed until required items are answered and isolations are restored.
A repair work order is opened from a failure in one step, and no second work order can be opened from the same failure. When it is opened the failure is in repair; when the operator accepts the job the failure is resolved; if the work order is cancelled the failure reopens. If the failure caused a production stop, a downtime record is kept automatically from detection to resolution.
Both are downloaded as PDFs from the work order detail. The service report contains work order, SLA, work permit, isolation, checklist, material, failure, downtime and status history sections. The acceptance protocol is available only for technically completed or operator-accepted work orders; texts are produced in the language of the request.
All products run on the same map, the same authorization model and the same asset records.
EAM · Maintenance Planning
Calendar and Counter-Based Preventive Maintenance
View detailsEAM · HSE & Permit to Work
Permit to Work, Lock-Out/Tag-Out and Certification Tracking
View detailsEAM · Contractors & SLA
Service Contracts, SLA and Contractor Work Sharing
View detailsEAM · Stock & Spare Parts
Plant Warehouses, Consumables and Spare Components
View detailsInvestment Management
Optimize your electricity distribution investments
View detailsMaintenance Management
Digitize your asset maintenance processes
View detailsInvestment Management · Performance
Duration, Schedule and Cost Measurement for Investments
View detailsMaintenance Management · Performance
Maintenance Duration, Efficiency and Staff Scorecards
View detailsInspection Management
Inspection Management: Drone and AI Grid Inspection
View detailsPower Quality
Power Quality Management Software
View detailsGrid Monitoring
Power System Management
View detailsOutage Management
Outage & EPDK Reporting
View detailsFacility Transfer · Art. 37 / 21
Article 37 Facility Transfer and Article 21 User-Built Facilities
View detailsGIS · Network Topology
Network Inventory, Topology and Feeder Management
View detailsDigital Twin · 3D
3D Grid Twin and Scenario Analysis
View detailsEngineering Analysis
Line Project Engineering Calculations
View detailsBusiness Intelligence
Management Dashboard, Benchmarking and Monitoring
View detailsField Operations
AKIM Field Management Application
View detailsFault Management
Fault Reporting and Response Management
View detailsEAM · Asset Registry
Plant Asset Registry and Warranty Tracking
View detailsEAM · Reliability
Downtime Records, Availability and SCADA Connection