Plant Asset Registry and Warranty Tracking
Asset registry for wind, solar, hydro and battery storage plants: sites, an asset tree from turbine down to cell group, technology-specific profiles, counters, component replacement history, warranty tracking and bulk import from Excel. The foundation module of GeoEner Energy Asset Management (EAM).
GeoEner EAM Plant and Asset Registry brings the physical assets of generation plants together in a single tree. Each site is recorded with its technology (wind, solar, hydro, battery storage or hybrid), installed capacity and coordinates. The asset tree starts at the site and goes down from turbine, rotor, blade, gearbox and generator; to inverter, MPPT and strings; to hydro unit, governor and penstock; to battery container, rack, module and cell group. The asset type catalog defines which type can sit under which parent and which plant technology it belongs to, so an asset added in the wrong place is rejected.
Turbines, inverters, hydro units and battery racks carry profiles used in filters, reports and KPIs: rated power, rotor diameter and hub height; AC rated power and DC capacity; head, flow and turbine type; nominal energy, rated power, cell chemistry and latest state of health. Cumulative counters such as operating hours, energy produced, start-stop count, equivalent full cycles, yaw rotations and charged/discharged energy are read manually or from SCADA. When a component is removed or replaced, the period it was installed is recorded; serial-numbered spare components are kept as spares at the site.
Warranty records can carry a counter limit (for example equivalent full cycles) and a minimum state-of-health threshold in addition to an end date; a warranty covers the asset's subtree and its status is calculated from the latest counter readings and battery profiles. For a pilot rollout, sites, the asset tree and profiles are bulk-imported from an Excel template: the file is validated in full first, and if there is a single error nothing is written. The EAM Dashboard summarizes open work orders, SLA status, failures, overdue maintenance, warranty alerts and availability per site.
EAM is multi-tenant: each tenant's data is isolated from the others, and users see either all sites or only the sites of the workspaces they belong to. Changes to EAM records are written to an audit log, and concurrent edits never silently overwrite another user's change. GeoEner EAM is a module family licensed separately on GeoEner.
Asset registry for wind, solar, hydro and battery storage plants: sites, an asset tree from turbine down to cell group, technology-specific profiles, counters, component replacement history, warranty tracking and bulk import from Excel. The foundation module of GeoEner Energy Asset Management (EAM).
Module by module.
Each site is recorded with its code, technology, installed capacity and coordinates. Coordinates are used in weather planning and technology in asset type compatibility; a site can be linked to the generation plant in GeoEner PSM.
Turbine, blade, pitch, main bearing, gearbox, generator, converter, yaw and tower; inverter, MPPT, string, tracker and combiner box; hydro unit, turbine, governor, excitation, penstock, gate and intake; BESS container, rack, module, cell group, PCS, BMS, HVAC and fire system; and shared types such as transformer, switchgear and meter are ready in the catalog. An asset can only be added or moved under an allowed parent type.
Turbines keep rated power, rotor diameter and hub height; inverters keep AC rated power and DC capacity; hydro units keep rated power, head, flow and turbine type; battery racks keep nominal energy, rated power, cell chemistry and latest state of health. Other manufacturer-specific data stays in the asset's free attributes.
Operating hours, energy produced, start-stop count, equivalent full cycles, yaw rotations, and charged and discharged energy readings come in manually or from SCADA. A counter can never go backwards; counter-based maintenance rules and warranty limits run on these readings.
When a component is replaced, the old part is removed, the new one installed and both periods are recorded with a reason. Serial-numbered major components are kept as spares at the site and picked from that list during replacement.
A warranty can carry a counter limit and a minimum state-of-health threshold in addition to its end date. It covers the asset's subtree; its status is calculated as valid, approaching, limit exceeded or expired and appears as an alert on the dashboard.
Sites, the asset tree and turbine, inverter, hydro and BESS profiles are bulk-imported with a downloadable Excel template. The file is validated in full first and errors are shown per row; if there is a single error nothing is written. Assets can be attached to an existing site and an existing parent asset.
Each tenant's data is isolated from the others, and this isolation is guarded by automated tests. Workspaces group sites by region or business unit; a user scoped to workspaces sees only those sites. Changes are written to an audit log that tenant administrators can view.
The tenant and its members are defined; sites are grouped into workspaces by region or business unit.
Sites, the asset tree and profiles are imported from the template; the file is validated in full first.
Turbine, inverter, hydro unit and battery rack profiles and cumulative counters are kept up to date.
Warranties are tracked by date, counter and state of health; component replacements are written to history.
Work orders, failures, maintenance, warranties and availability per site are seen on one dashboard.
Keep the assets, component history and warranties of your wind, solar, hydro and battery storage portfolio in one registry.
See which asset is approaching which limit from profile, counter and warranty data, and file warranty claims on time.
If you serve several plant owners, each owner's data stays isolated in its own tenant.
Wind, solar, hydro, battery storage and hybrid plants are supported. The asset type catalog has ready types from turbine down to blade, gearbox and generator; inverter, MPPT and strings; hydro unit, governor and penstock; and BESS container, rack, module and cell group. Shared types such as transformer, switchgear and meter are used across technologies.
Sites, the asset tree and turbine, inverter, hydro and BESS profiles are bulk-imported with the Excel template downloaded from the Pilot Data Import screen. The file is validated in full first and errors are shown per row; if there is a single error nothing is written. The import only adds records and never updates existing ones; assets can be attached to an existing site and parent asset.
No. A warranty record can carry a counter limit such as equivalent full cycles and, for batteries, a minimum state-of-health threshold in addition to the end date. A warranty covers the asset's subtree; its status is calculated from the latest counter readings and battery rack profiles, and approaching or exceeded warranties appear as alerts on the EAM Dashboard.
GeoEner EAM is multi-tenant: each tenant's data is isolated from the others, and this isolation is guarded by automated tests. Within a tenant, sites are grouped into workspaces; a user scoped to workspaces sees only the sites of the workspaces they belong to. Changes are written to an audit log.
All products run on the same map, the same authorization model and the same asset records.
Business Intelligence
Management Dashboard, Benchmarking and Monitoring
View detailsEAM · Maintenance Planning
Calendar and Counter-Based Preventive Maintenance
View detailsEAM · Reliability
Downtime Records, Availability and SCADA Connection
View detailsEAM · Stock & Spare Parts
Plant Warehouses, Consumables and Spare Components
View detailsInvestment Management
Optimize your electricity distribution investments
View detailsMaintenance Management
Digitize your asset maintenance processes
View detailsInvestment Management · Performance
Duration, Schedule and Cost Measurement for Investments
View detailsMaintenance Management · Performance
Maintenance Duration, Efficiency and Staff Scorecards
View detailsInspection Management
Inspection Management: Drone and AI Grid Inspection
View detailsPower Quality
Power Quality Management Software
View detailsGrid Monitoring
Power System Management
View detailsOutage Management
Outage & EPDK Reporting
View detailsFacility Transfer · Art. 37 / 21
Article 37 Facility Transfer and Article 21 User-Built Facilities
View detailsGIS · Network Topology
Network Inventory, Topology and Feeder Management
View detailsDigital Twin · 3D
3D Grid Twin and Scenario Analysis
View detailsEngineering Analysis
Line Project Engineering Calculations
View detailsField Operations
AKIM Field Management Application
View detailsFault Management
Fault Reporting and Response Management
View detailsEAM · Work Orders & Failures
Plant Work Orders, Failure Records and Service Reports
View detailsEAM · HSE & Permit to Work
Permit to Work, Lock-Out/Tag-Out and Certification Tracking
View detailsEAM · Contractors & SLA
Service Contracts, SLA and Contractor Work Sharing
View detailsTrusted By